Collect solar data with the highest possible accuracy using the Hukseflux SR20 Secondary Standard Pyranometer.
#9057
Recommended when measurement accuracy is the top priority, the Hukseflux SR20 is a thermopile pyranometer that is compliant with the highest category in the ISO 9060 standard: secondary standard.
This high accuracy thermopile-based sensor measures global horizontal irradiance (GHI) and has a spectrally flat response across the full solar spectrum. The SR20 generates a small voltage signal that is proportional to the solar radiation flux, expressed in W/m2.
The SR20 is compatible with all Symphonie series data loggers when equipped with a Symphonie® SCM Card (SCM #6646, used with the SymphoniePLUS®3 Data Logger and older) or Pro Signal Conditioning Module (P-SCM #9128, used with the SymphoniePRO® Data Logger).
This sensor comes with a full sensor-specific characterization to the parameters of ISO 9060, calibration certificate, sun screen, and 5 m (16.4') cable. Note that as with all thermopile pyranometers, regularly scheduled maintenance is imperative to achieve the sensor’s specified performance.
Hukseflux SR20 Pyranometer (#9057) | |
---|---|
Description | |
Sensor type | Thermopile solar radiation sensor; ISO 9060 ‘Secondary Standard’ compliant |
Applications |
|
Sensor range | 0 W/m2 to 4000 W/m2 |
Spectral range | 285 nm to 3000 nm |
Instrument compatibility |
|
Output signal | |
Signal type | Microvolt proportional to total solar radiation |
Transfer function | Included on calibration certificate; for use with RNRG Symphonie see application note "Using Thermopile Pyranometers on Symphonie Loggers" |
Accuracy | Secondary Standard per ISO 9060 |
Calibration |
Calibration sheet included with each sensor defines output in microvolts per Watt/square meter; traceable to World Radiometric Reference (WRR) Calibration uncertainty < 1.2% (k=2) as specified by Hukseflux |
Output signal range | -0.1 mV to + 50 mV |
Drift | Less than 0.5% per year |
Power requirements | |
Power Required | Zero (passive sensor) |
Installation | |
Mounting | Mounts to tower with RNRG tower top mounting platform (9104) or side mounting boom (6772) (plane of array capable) |
Tools required |
|
Environmental | |
Operating temperature range | -40 °C to 80 °C (-40 °F to 176 °F) |
Operating humidity range | 0 to 100% |
Physical | |
Connections |
Bare wire leads from cable connect directly to logger see also logger user's manual for wiring diagram |
Cable length | 5 m (16.4 feet) |
Weight | 1.2 kg (2.6 lbs) |
Dimensions | 150 mm X 85 mm (5.9 inches X 3.3 inches) |
Materials | |
Cable | Shielded 2 conductor |
Detector | Thermopile |
Enclosure | IP67 weatherproof anodized aluminum enclosure and stainless steel hardware |
For Software downloads and details click here